Configure UNI

Before you begin

You must enable Flex UNI to create a Switched UNI service.

About this task

Use the following procedure to configure a Transparent Port UNI or Switched UNI by mapping an I-SID to a port or MLT and VLAN together.

Note

Note

If you configure a T-UNI to terminate on a port or MLT on a switch in a vIST switch cluster, you must also configure the T-UNI I-SID on the other switch of the vIST switch cluster. You must configure the T-UNI I-SID on both switches of a vIST pair. You do not need to assign an actual port or MLT to the T-UNI on the second switch.

You must first create a type of service instance identifier (I-SID) to create the different types of services available. After you create an I-SID you can add members (ports or MLTs) to the I-SID to create end-points for the service.

Procedure

  1. In the navigation pane, expand Configuration > Fabric.
  2. Select ISID.
  3. Select the Service tab.
  4. To create a Transparent Port UNI service:
    1. Select Insert.
    2. Select elan Transparent in the Type field.
    3. Enter the I-SID in the Id field.
  5. To create a Switched UNI service:
    1. Select Insert.
    2. Select elan in the Type field.
    3. Enter the I-SID in the Id field.
  6. Select Insert.

Service Field Descriptions

Use the data in the following table to use the Service tab.

Name

Description

ID

Specifies a unique value to identify the service associated with this entry.

Type

Specifies the type of service associated with this entry.

MacLimitEnable

Indicates whether the MAC limit is enabled (true) or disabled (false).

MaxMacLimit

Indicates the maximum learned value of the MAC address for each service I-SID.

Action

Specifies I-SID related actions.

OriginBitMap

Specifies the origin of the I-SID.

VnId

Identifies the VXLAN service associated with this I-SID.

Name

Note:

This field does not apply to all hardware platforms.

Specifies the name of the I-SID.